B95W
Description
05_Beschreibung_en.fm - V1.0 - 1.8.17
83 / 306
5
11
Monitoring the warning stages:
Tab. 5-8 Monitoring of warning stages
Engine exhaust
train protection
level
Filter load
[%]
Requirement for starting
regeneration
Regeneration
mode
Control light
Engine/system
reaction
(when load is
excessive)
Particle filter
regeneration
Engine
diagnos-
tics
0
Normal
< 63
-
OFF
OFF
none
1
Heat mode
63
-
Heat mode
OFF
OFF
none
2
Stoppage
regeneration
100
- Park break locked
- Direction switch in
neutral
- Select “Particle filter
regeneration”
Stoppage
Slow flashing
(2 second beat)
OFF
none
3
Warning
110
- Park break locked
- Direction switch in
neutral
- Select “Particle filter
regeneration”
Stoppage
Rapid flashing
(1 second beat)
TO
Power reduction
30 %
4
Engine Off
125
- Park break locked
- Direction switch in
neutral
- Start using SERDIA
Stoppage
Rapid flashing
(1 second beat)
Flashing
Power reduction
30 %
- Engine speed
limited to 1200 rpm
5
Filter change
156
No regeneration
possible (=filter change)
regeneration
no longer
possible
Rapid flashing
(1 second beat)
Flashing
Power reduction
30 %
- Engine speed
limited to 1200 rpm
Содержание B95W
Страница 2: ......
Страница 8: ...B95W Table of contents 6 306 1 01_Inhaltsverzeichnis_enIVZ fm V1 0 1 8 17 10 ...
Страница 52: ...B95W Description 50 306 5 05_Beschreibung_en fm V1 0 1 8 17 11 ...
Страница 58: ...B95W Description 56 306 5 05_Beschreibung_en fm V1 0 1 8 17 11 ...
Страница 206: ...B95W Maintenance 204 306 6 06_Wartung und Pflege_en fm V1 0 1 8 17 20 ...
Страница 208: ...B95W Operation 206 306 7 07_Bedienung_en fm V1 0 1 8 17 26 ...
Страница 238: ...B95W Operation 236 306 7 07_Bedienung_en fm V1 0 1 8 17 26 Optional SAE control system Fig 7 14 Lever control 3 5 4 1 2 ...
Страница 272: ...B95W Transport 270 306 8 08_Transport_en fm V1 0 1 8 17 27 ...
Страница 302: ...B95W Troubleshooting 300 306 10 10_Fehlerbeseitigung_en fm V1 0 1 8 17 30 ...
Страница 309: ......
Страница 310: ...http www yanmar eu MOBILE EXCAVATOR ...