B95W
Maintenance
06_Wartung und Pflege_en.fm - V1.0 - 1.8.17
157 / 306
6
20
Tighten the filter to a torque of approximately 10 - 12 Nm.
Bleed the fuel system.
Perform a test run.
Check the filter for leaks.
Clean the inlet strainer and check it for damage.
Bleeding the fuel system
The fuel system is bled via the electric fuel pump.
To ensure that no error messages are created, you must not attempt to start the
system during the bleeding process.
Turn on the ignition.
J
The electronic fuel pump switches on for 20 seconds to bleed the fuel system
and establish the required fuel pressure.
Wait until the electric fuel pump has been switched off by the control unit.
Turn off the ignition.
Repeat the process at least four times until the fuel system is bled.
Check the fuel prefilter and the fuel filter for leaks after starting the engine.
Notice
A brief delay in maintenance does not result in lower filter efficiency.
Содержание B95W
Страница 2: ......
Страница 8: ...B95W Table of contents 6 306 1 01_Inhaltsverzeichnis_enIVZ fm V1 0 1 8 17 10 ...
Страница 52: ...B95W Description 50 306 5 05_Beschreibung_en fm V1 0 1 8 17 11 ...
Страница 58: ...B95W Description 56 306 5 05_Beschreibung_en fm V1 0 1 8 17 11 ...
Страница 206: ...B95W Maintenance 204 306 6 06_Wartung und Pflege_en fm V1 0 1 8 17 20 ...
Страница 208: ...B95W Operation 206 306 7 07_Bedienung_en fm V1 0 1 8 17 26 ...
Страница 238: ...B95W Operation 236 306 7 07_Bedienung_en fm V1 0 1 8 17 26 Optional SAE control system Fig 7 14 Lever control 3 5 4 1 2 ...
Страница 272: ...B95W Transport 270 306 8 08_Transport_en fm V1 0 1 8 17 27 ...
Страница 302: ...B95W Troubleshooting 300 306 10 10_Fehlerbeseitigung_en fm V1 0 1 8 17 30 ...
Страница 309: ......
Страница 310: ...http www yanmar eu MOBILE EXCAVATOR ...