For Service Engineers
Service Information
SI1906002E-001=YSP10 installation and adjustment procedures
99/120
Release the Emergency Stop button.
Press the [Move Adjust Pos.] button to move the camera axis to the mark position
located at the center of front conveyor.
Press the [Execute] button.
Check that the measured values are within acceptable ranges. Fill in the values in
the check sheet.
Acceptable ranges
Item
Acceptable range
Camera Angle
0 +/- 0.5 degree
Scale X, Scale Y
18.94 +/-
0.2μm
Press the [Yes] button in the confirmation message box to save the measured
data. Continue with next steps.
Displayed after
executing the
adjustment.