For Service Engineers
Service Information
SI1906002E-001=YSP10 installation and adjustment procedures
81/120
13.10. Adjust camera lighting conditions
Adjust lighting conditions for the mask camera, PCB camera and inspection camera.
Note
Normally, it doesn’t need to adjust camera lighting conditions at the installation. However, if a mark
recognition error occurs during adjustment and the problem is not resolved after the mark adjust,
adjust camera lighting conditions.
13.10.1. Check lightness adjustment tools
Lightness adjustment tools are to be specified in the CalibSm screens for camera lightness adjustment.
Confirm required adjustment tools referring to the following table.
Tool appearance and
features
Part number
CalibSm setting
designation
Remark
Two-tone gray
No 3mm hole
No part number label
・
KM1-M8806-00
KM1-M8806-0XX
Two-tone gray
3mm hole
Part number label on tool’s
side
・
KM1-M8806-10
・
KM1-M8806-11
See the tool’s label for
identification.
KM1-M8806-1XX
KM1-M8806-11
17mm square
Mono-tone gray
・
KGT-M8806-00
KGT-M8806-0XX
Two- or mono-tone gray
Part number label
11, 17 or 35mm square
Chamfered on one corner
・
KHW-M8896-A0
(two-tone 35mm square)
・
KHW-M8806-B0
(mono-tone 17mm square)
・
KHW-M8806-C0
(mono-tone 35mm square)
・
KHW-M8806-D0
(mono-tone 11mm square)
KHW-M8806-XXX
KHW-M8806-C0
Two- or mono-tone gray
Part number label
11, 17 or 35mm square
Chamfered on two corners
・
KMC-M8806-A0
two-tone 35mm square)
・
KMC-M8806-B0
(mono-tone 17mm square)
・
KMC-M8806-C0
(mono-tone 35mm square)
・
KMC-M8806-D0
(mono-tone 11mm square)
KMC-M8806-XXX
KMC-M8806-C0