For Service Engineers
Service Information
SI1906002E-001=YSP10 installation and adjustment procedures
79/120
Remove a test board.
Adjust the board transfer height (Z)
Select “PCB Carry Height” by tapping its check box. Deselect all other items.
Check for safety in and around the machine so that return-to-origin operation can
be safely performed.
Step 6. Release the Emergency Stop button and press [Z1] at [Trace] column.
Set 2 test boards on the entrance/exit area of center and left conveyor and center
and right conveyor. Make sure that the test boards don’t stuck at the entrance/exit area of
conveyors.
The board is not stuck.
→
Start the next adjustment.
The board is stuck.
→
Perform the board transfer height adjustment (Step 16).
Press the [Move Axis] button.
Move the Z-axis to the position to make the conveyors do not stuck.