![Yamaha YSP10 Скачать руководство пользователя страница 76](http://html.mh-extra.com/html/yamaha/ysp10/ysp10_service-information_901779076.webp)
For Service Engineers
Service Information
SI1906002E-001=YSP10 installation and adjustment procedures
76/120
Check that the [Measured] values (X and Y) of [Standard] are within acceptable
range.
When the values are within range, fill in the check sheet with the values and finish without saving data.
When the values are out of range, save the data and redo from step 4.
Check that the [Measured] values (X and Y) of [Standard] are within acceptable
range.
When the values are within range, fill in the check sheet with the values and finish without saving data.
When the values are out of range, save the data and redo. The values are out of range then, redo from
“13.7 13.7Adjust the R-axis initial positions”.
Item
Acceptable range
Standard (of Force Point)
+/- 0.0003 or below
Standard (of Force Point) 2
+/- 0.01 or below
Values shall be within range.
Values are out of range.
Press the [Yes] button and redo from step
4
Values are within range.
Press the [No] button and finish.
Standard 2