109
En
Using multi-zone configuration
AD
V
ANCED
OPERA
T
ION
English
■
Using the internal amplifiers of this unit
If you want to use one internal amplifier (SP1 or SP2) of this unit
Connect the Zone 2 or Zone 3 speakers directly to the SP1 or SP2 speaker terminals and select either “[SP1]” or “[SP2]”
for “AMP” (see page 91).
If you want to use two internal amplifiers (SP1 and SP2) of this unit
Connect the Zone 2 and Zone 3 speakers directly to the SP1 and SP2 speaker terminals and select “BOTH” for “AMP”
(see page 91).
You can select the zone you want to control by using the
control buttons on the front panel or on the remote control.
■
Selecting Zone 2 or Zone 3
Front panel operations
1
Press
P
ZONE 2 ON/OFF
or
P
ZONE 3
ON/OFF
on the front panel to individually
turn on or off Zone 2 or Zone 3.
2
Press
P
ZONE CONTROLS
on the front
panel repeatedly to select the zone you want
to control.
Each time you press
P
ZONE CONTROLS
, the
front panel display changes as shown below, and the
indicator for the currently selected zone flashes for
approximately 10 seconds. However, no indicator
flashes when the main zone is selected.
ZONE2
Controls the Zone 2 amplifier or tuner functions.
ZONE3
Controls the Zone 3 amplifier or tuner functions.
Important safety notice
The SP1 or SP2 speaker terminals of this Receiver should not be connected to a Passive Loudspeaker Selector Box or
more than one loudspeaker per channel.
Connection to a Passive Loudspeaker Selector Box or multiple speakers per channel could create an abnormally low
impedance load resulting in amplifier damage. See this owner’s manual for correct usage.
Compliance with minimum speaker impedance information for all channels must be maintained at all times. This
information is found on the back panel of your Receiver.
R
L
+
–
SP2
SINGLE
R
L
+
–
+
–
BI-AMP
SURROUND BACK/
PRESENCE/ZONE 2/ZONE 3
ZONE 2/ZONE 3
R
L
SP1
+
–
+
–
Third zone
(Zone 3)
This unit
Second zone
(Zone 2)
Controlling Zone 2 or Zone 3
ZONE2
ZONE3
No indicator flashes
when the main zone is selected.