4-11
Outboard motor troubleshooting
S
ymptom 1: Discharged battery.
S
ymptom 1: Y-COP lock and unlock do not function.
Buzzer comes on, oil
pressure alert indica-
tor comes on
Insufficient engine oil
Check the engine oil level.
Check for engine oil leakage.
Check the valve seals and valves.
Check the piston rings.
Engine oil pressure de-
crease
Check the oil pressure switch.
Check the oil pump.
Check the oil strainer.
Check the oil passages (power unit
and the oil pump).
Replace the oil filter.
Symptom 2
Cause
Checking steps
See
page
Low voltage indicator
activates on the
gauge
Battery performance de-
crease
Check the battery capacity and spe-
cific gravity.
Short, open, or loose con-
nection in charging circuit
Check the battery cable and termi-
nals for proper connections.
Check the charging circuit for wiring
connection and damage.
Lighting coil malfunction
Measure the lighting coil output peak
voltage.
Measure the lighting coil resistance.
Rectifier/regulator malfunc-
tion
Measure the rectifier/regulator out-
put peak voltage.
Check the rectifier/regulator for con-
tinuity.
Symptom 2
Cause
Checking steps
See
page
There is an answer-
back (beep)
Y-COP remote control
transmitter malfunction
Check the button cell battery volt-
age.
—
Replace with a spare remote control
transmitter.
—
Short, open, or loose con-
nection of the wire harness
Check the Y-COP circuit.
—
Symptom 2
Cause
Checking steps
See
page
Содержание F30A 2018
Страница 1: ...6BG 28197 ZX 11 LIT 18616 03 84 USA CAN AUS and NZL Worldwide 6BG 6BT 6BG 6BT ...
Страница 22: ...1 Specification Specification data 1 1 External dimensions 1 1 Clamp bracket dimensions 1 9 ...
Страница 35: ...2 3 Electronic control system Electrical components 3 4 5 6 7 8 9 10 11 1 2 ...
Страница 178: ...7 23 Wire harness 2 3 1 a c b 3 4 5 ...
Страница 342: ...Jul 2018 ABE E ...