TROUBLESHOOTING CHART
WEAK OR NO DC CURRENT
No load engine speed inspection.
9
Operate the engine with no load.
9
Measure after warming up the engine.
3,000 r/min / Economy control switch-ON
4,500 r/min / Economy control switch-OFF
GOOD
OUT OF SPECIFICATION
Check the throttle control system.
Refer to “THROTTLE CONTROL SYSTEM” in
CHAPTER 6.
Check the DC circuit breaker.
GOOD
DISCONNECTED
Replace the DC protector.
DC coil DC voltage inspection
9
Connect sub coil
2
White leads.
9
Economy control switch-OFF.
9
Start the engine with no load.
9
Measure the voltage. (Tester range: AC 20 V)
GOOD
TOO LOW
DOES NOT GENERATE
W
W
W
W
O
O L
L
2
DC coil AC voltage:
14.5–21.7 V at 20 °C (68 °F)
Replace the rectifier.
DC coil resistance inspection
9
Stop the engine.
9
Measure the resistance between the-White.
(Tester range:
Ω ×
1)
SPECIFICATION
OUT OF SPECIFICATION
W
W
W
W
2
DC coil resistance:
0.098
Ω
± 20 % at 20 °C (68 °F)
Replace the stator assembly.
Magnetic force is weak.
Replace the magneto rotor.
7DK40-05 6/12/09 6:01 PM Page 44
Содержание EF2000iS - Inverter Generator
Страница 2: ...7DK40 Cover 4 6 09 9 18 AM Page 2 ...
Страница 13: ...7DK40 00 6 15 09 2 54 PM Page 11 ...
Страница 17: ...7DK40 00 6 15 09 2 54 PM Page 15 ...
Страница 21: ...7DK40 00 6 15 09 2 54 PM Page 19 ...
Страница 223: ...ELEC 7DK40 05 6 12 09 6 01 PM Page 41 ...
Страница 233: ...ELEC 7DK40 05 6 12 09 6 01 PM Page 51 ...
Страница 255: ...TRBL 7DK40 06 6 15 09 10 30 AM Page 22 ...
Страница 310: ...7DK40 07 6 15 09 3 01 PM Page 55 ...
Страница 311: ...7DK40 Cover 4 6 09 9 18 AM Page 2 ...