VX-6E O
PERATING
M
ANUAL
96
Set Mode Item 30
[
INT MD
]
Function
: Selects the Internet Link Connection mode.
Available Values
: SRG/FRG
Default
: SRG (Single DTMF Digit is appended at the beginning of each transmission)
Set Mode Item 31
[
INT.A/M
]
Function
: Enables/Disables the DTMF Autodialer feature while operating using the Internet
Connection feature.
Available Values
: MANUAL/AUTO
Default
: MANUAL
Set Mode Item 32
[
INT.SET
]
Function
: Selects the memory register for an Access Number (DTMF code) for non-
WIRES™ Internet Link System access.
Available Values
: F 0 - F63
Default
: F 1
Set Mode Item 33
[
LAMP
]
Function
: Selects the LCD/Keypad Lamp mode.
Available Values
: KEY/CONT/OFF
Default
: KEY
KEY:
Illuminates the Keypad/LCD for five seconds when you rotate the
DIAL
knob
or press any key or switch (except the
PTT
switch).
CONT:
Illuminates the Keypad/LCD continuously.
OFF:
Disables the Keypad/LCD lamp illumination.
Set Mode Item 34
[
LED LT
]
Function
: Illuminates the
STROBE
glows continuously in white (useful as emergency
flashlight at night).
Set Mode Item 35
[
LOCK
]
Function
: Selects the Control Locking lockout combination.
Available Values
: KEY/DIAL/K+D/PTT/P+K/P+D/ALL
Default
: K+D
Note
: “K” = “Key;” “D” = “Dial;” and “P” = “PTT.”
Set Mode Item 36
[
M/T-CL
]
Function
: Selects the
MONI
switch (just below the
PTT
switch) function.
Available Values
: MONI/T-CALL
Default
: T-CALL
MONI: Pressing the
MONI
switch causes the Noise/Tone Squelch to be over-ridden,
allowing you to listen for weak (or non-encoded) signals.
T-CALL: Pressing the
MONI
switch activates a 1750-Hz burst tone, used for repeater
access in many countries (especially in Europe).