Revision 1.1
WebSwitch™ Users Manual
Outlet
This drop down menu is used to select the outlet for which the options below will apply.
-
Outlet 1
or
Outlet 2
: Selects the built-in outlets.
Automatic Reboot
When this option is set to
On
, WebSwitch™ will operate in
Automatic Reboot
mode. In
Automatic
Reboot
mode, WebSwitch™ is configured to periodically confirm that another device (such as a
server, computer, router, etc.) is working by sending ping requests to the device. WebSwitch™
expects a response after each ping. If a pre-set number of ping requests fail, it is assumed that the
device is not functioning properly. WebSwitch™ will attempt to restore the device to normal
operation by rebooting the device. In
Automatic Reboot
mode, users still have the ability to
manually reboot the device from a remote location over the network. The default setting for this field
is
Off
.
When automatic reboot is set to
Off
, WebSwitch™ will operate in
Normal
mode. In
Normal
mode,
WebSwitch™ will only change the state of the outlets when commanded by a user.
Outlet Description
This text field is used to describe the function of the selected outlet. The text appears to the left of
the corresponding outlet status on the
Control Page
, and in the email message when email alerts
are enabled. Up to 24 characters may be entered in this field. The default text is
Outlet #
.
On Button Label
The text entered in this field appears in the 'On' button for the corresponding outlet on the
Control
Page
. Up to 15 characters may be entered in this field. The default text is
ON
.
Off Button Label
The text entered in this field appears in the 'Off' button for the corresponding outlet on the Control
Page. Up to 15 characters may be entered in this field. The default text is
OFF
.
Pulse/Reboot Button Label
The text entered in this field appears in the 'Pulse' button for the corresponding outlet on the Control
Page. Up to 15 characters may be entered in this field. The default text is
REBOOT
.
On Status Text
The text in this field specifies the text that will be displayed in the status field in the Control Page and
in email messages when the corresponding outlet is on. Up to 15 characters may be entered in this
field. The default text is
ON
.
Off Status Text
The text in this field specifies the text that will be displayed in the status field in the Control Page and
in email messages when the corresponding outlet is off. Up to 15 characters may be entered in this
field. The default text is
OFF
.
Xytronix Research & Design, Inc.