37
Troubleshooting
TROUblESHOOTING CHART
SYMPTOM
PROBABLE CAUSE
REMEDY
Motor will not run.
Circuit overload.
Determine if voltage is on. If not,
check wall breaker or fuse.
Secondary circuit overload.
Check primary and secondary
fuses on transformer.
Motor overload.
Reset thermal overload button
on pump motor or thermal
overload in electrical box.
Contact Customer Service.
No discharge at
nozzle when trigger
mechanism is
squeezed.
Water turned off.
Check incoming water supply.
Increase hose diameter and
provide adequate water supply
(20 PSI, 6 GPM).
Low or fluctuating
pressure.
Inadequate water supply.
Pump sucking air. (Prime
eliminated.)
Tighten all water intake
connections.
Eliminate leaks in intake line.
High pressure detergent
valve is open without the
end of the hose inserted
into detergent (causes
vacuum leak and eliminates
prime).
Close valve or submerge
detergent hose into solution.
Reprime pump.
Kink in high pressure
discharge hose.
Replace kinked high pressure
hose.
Adjustable grip on dual
lance is not in high pressure
mode.
Turn grip counterclockwise to
move to high pressure.
Obstructed or worn spray
nozzle.
Remove, clean or replace.
Damaged or obstructed
valve assy. on pump.
Remove, clean or replace.
Pump packings worn.
Replace packings.
Unloader/Bypass valve not
operating correctly.
Repair or replace.
Oil appears milky or
foamy.
Water in oil.
Change pump oil. Fill to proper
level.
Oil leaking from pump.
Worn seals or o-rings.
Contact Customer Service.
troubleshooting
Содержание X-HW13008GENNG
Страница 1: ...operation manual X HW13008GENNG X HW33008GENNG NATURAL GAS HOT WATER PRESSURE WASHER...
Страница 2: ...2...
Страница 14: ...14 Features 0 Operator s Manual Hg series features HG SERIES FEATURES 032905 RZ features...
Страница 39: ...39...
Страница 40: ...40 If you need assistance with the assembly or operation of this Pressure Washer please call 1 866 770 1711...