73
X10
RST
C0
X11
CNT
C0
K10
C0
( )
Y0
Power-off retentive counter will keep the current value and counter coil status when the
power is off.
Increase count the OFF to ON times of M0.
When the count value reaches set value (value of K or D), the count coil will be ON.
When M1 is ON, the count coil of HSC0 reset, the current value becomes 0.
DCNT
Output
32 bits non power-off retentive
increase count, the drive of count
coil
DCNT C0
K8
Operand: K, D
DCNT_D
Output
32 bits power-off retentive
decrease count, the drive of
count coil
DCNT_D HC0
K8
Operand: K, D
RST
Reset
Reset the output coil, clear the
current count value
Operand: C, HC, HSC
C0 increase counts the X11 OFF
to ON times. When C0 reaches
K10, C0 will become OFF to ON.
When X11 becomes OFF to ON,
the C0 current value will keep
increasing, and the C0 coil will
still be ON. When X10 is ON,
reset the C0 coil.
Internal counter
programming
High speed counter programming