231
(#14 module)
QD11400~QD11499
(#15 module)
100
6678~66DB
26232~26331
QD11500~QD11599
(#16 module)
100
66DC~673F
26332~26431
QD20000~QD20099(#1
BD)
100
68D0~6933
26832~26931
SD
SD0~SD4095
4096
7000~7FFF
28672~32767
TD
TD0~TD4095
4096
8000~8FFF
32768~36863
CD
CD0~CD4095
4096
9000~9FFF
36864~40959
ETD
ETD0~ETD39
40
A000~A027
40960~40999
HD
※
1
HD0~HD6143
6144
A080~B87F
41088~47231
HSD
※
1
HSD0~HSD1023
1024
B880~BC7F
47232~48255
HTD
※
1
HTD0~HTD1023
1024
BC80~C07F
48256~49279
HCD
※
1
HCD0~HCD1023
1024
C080~C47F
49280~40303
HSCD
※
1
HSCD0~HSCD39
40
C480~C4A7
50304~50343
FD
※
2
FD0~FD8191
8192
C4C0~E4BF 50368~58559
SFD
※
2
SFD0~SFD4095
4096
E4C0~FC2F
58560~64559
FS
※
2
FS0~FS47
256
F4C0~F4EF
62656~62703
Note:
1. the power down holding area is marked with *1, and the flash area is marked with *2.
2: the address in the above table is used when PLC is the lower computer and Modbus RTU
or MODBUS ASCII protocol is used for communication, the general upper computer is:
SCADA/HMI/PLC.
3: if the upper computer is PLC, program according to Modbus RTU or MODBUS ASCII
protocol.
4: if the upper computer is SCADA or HMI, there are two situations: the first one has the
Xinje driver, for example: Xinje HMI / Zijinqiao SCADA.
The program can be written directly by using PLC internal soft components (Y0 / M0); for
the second type, Modbus RTU or Modbus ASCII is selected if there is no Xinje driver, and
then use the addresses in the table above to define the data variables.
5: input and output point is octal, please calculate corresponding input and output point
MODBUS address according to octal, for example: MODBUS corresponding to Y0,
the address is H6000, the Modbus address corresponding to Y10 is H6008 (not H6010), and
the Modbus address corresponding to Y20 is H6010 (not H6020).
6: when the Modbus address exceeds 32767, it needs to be expressed in hexadecimal, and "0"
should be added before the address. For example: MODBUS of HD0 is 41088 in decimal
(beyond 32767), and 41088 cannot be written into the software, so it needs to be expressed in
hexadecimal as H0A080.
7: Calculation of Modbus address of X and Y, taking X as an example, the calculation of
Modbus address of Y is the same as that of X.
X0: 20480 X10: 20480+8 X20: 20480+16 X30: 16384+24
…
X10000: 20736 X10010: 20736+8 X10020: 20736+16
…
X10200: 20800 X10210: 20800+8 X10220: 20800+16
…