282
S3+34
auto-tuning time
cumulative
0
~
4294967296 (unit: ms)
Internal usage
parameters of the
system
Manual control part (read only parameters, only for monitoring)
S3+24
current target
temperature
-32767~32767
Internal usage
parameters of the
system
S3+25
Need to update target
temperature
0: no need
1: need
16-bit no sign,
internal usage
parameters of the
system
S3+26
Number of times to
reach target
temperature
0~65535
Internal usage
parameters of the
system
S3+27
PID upper limit of
operational range
-32767~32767
Internal usage
parameters of the
system
S3+28
PID lower limit of
operational range
-32767~32767
Internal usage
parameters of the
system
S3+30
High voltage time when
PID uses Y to output
0
~
4294967296 (unit: ms)
Internal usage
parameters of the
system
S3+32
Sampling temperature
after last filtering
The filtered temperature acquired
in the last sampling time (the
input filter constant in the
advanced mode needs to be set
first)
Floating point,
internal usage
parameters of the
system
S3+34
Last temperature
deviation
Floating point,
internal usage
parameters of the
system
S3+36
Value of last integral
term
digital value corresponding to Ui
of the last sampling time
Floating point,
internal usage
parameters of the
system
S3+38
Value of last
differential term
digital value corresponding to Ud
of the last sampling time
Floating point,
internal usage
parameters of the
system
S3+40
Last PID output
Floating point,
internal usage
parameters of the
system
Note: When the auto-tuning mode is changed to manual control, the value in the original
address of S3+24~S3+40 will be overwritten by the value in manual control mode.