Silkscreen
Indicator and
Button
Description
Health status
indicator
● Off: The device is powered off or faulty.
● Blinking red at 1 Hz: A major alarm has been
generated on the system.
● Blinking red at 5 Hz: A critical alarm has been
generated on the system.
● Steady green: The device is operating
properly.
OCP 3.0 NIC
presence
indicator
Indicates whether the FlexIO card is detected.
● Off: The FlexIO card is not detected.
● Blinking green at 0.5 Hz: The FlexIO card is
detected but is not powered on.
● Blinking green at 2 Hz: The FlexIO card is
detected and has just been inserted.
● Steady green: The FlexIO card is detected
and the power supply is normal.
Power button/
indicator
Power indicator:
● Off: The device is powered off.
● Steady green: The device is powered on.
● Blinking yellow: The iBMC is starting. The
power button is locked and cannot be
pressed. The iBMC is started in about 1
minute, and then the power indicator is
steady yellow.
● Steady yellow: The device is in the standby
state.
Power button:
● When the device is powered on, you can
press this button to gracefully shut down the
OS.
NOTE
For different OSs, you may need to shut down the
OS as prompted.
● When the device is powered on, you can hold
down this button for 6 seconds to forcibly
power off the device.
● When the power indicator is steady yellow,
you can press this button to power on the
device.
FusionServer 5288 V7 Server
Technical White Paper
5 Hardware Description
Issue 01 (2023-07-20)
Copyright © xFusion Digital Technologies Co., Ltd.
11