NO TE
● When a single fan is faulty, the highest operating temperature is 5°C (9°F) lower than the
rated value.
● When a single fan is faulty, the system performance may be affected.
● It is recommended that servers be deployed at an interval of 1 U to reduce server noise
and improve server energy efficiency.
● When the rear I/O modules are configured with GPU cards, HDDs, or NVMe drives, 8080+
fan modules are required.
● It is recommended that servers be deployed at an interval of 1U to reduce server noise and
improve server energy efficiency.
● Liquid-cooled CPUs are not supported. Currently, CPUs whose package type is 4x XCC
+ 4x HBM are not supported.
A.4 Nameplate
Certified Model
Remarks
H52H-07
Global
A.5 RAS Features
The server supports a variety of Reliability, Availability, and Serviceability (RAS)
features. You can configure these features for better performance.
For details about RAS features, see the
FusionServer Intel Eagle Steam Platform
RAS Technical White Paper.
A.6 Sensor List
Sensor
Description
Component
Inlet Temp
Air inlet temperature
Right mounting ear
Outlet Temp
Air outlet temperature
BMC card
PCH Temp
PCH bridge temperature
Mainboard
PCH Status
PCH chip fault diagnosis
health status
Mainboard
1711 Core Temp
Core temperature of the
BMC management chip
BMC card
SSD Max Temp
Maximum SSD
temperature (reported by
BMA)
SSD
FusionServer 5288 V7 Server
Technical White Paper
A Appendix
Issue 01 (2023-07-20)
Copyright © xFusion Digital Technologies Co., Ltd.
127