A.3 Operating Temperature Limitations
Table A-7
Operating temperature limitations
Configuratio
n
Maximum
Operating
Temperature 30
℃
(86°F)
Maximum
Operating
Temperature 35°C
(95°F)
Maximum
Operating
Temperature 40°C
(104°F)
Single-RAID
or dual-RAID
configuration
(with built-in
drive
modules)
● CPUs with TDP
less than or
equal to 205 W
are supported
(excluding 6434
and 6434H
CPUs).
● 6414U and
8450H CPUs are
supported.
● The rear I/O
modules are
configured with
HDDs and NVMe
drives.
● The rear I/O
modules are
configured with
A2 and A30 GPU
cards.
● CPUs with TDP
less than or
equal to 205 W
are supported
(excluding 6434
and 6434H
CPUs).
● The rear I/O
modules are
configured with
A2 and A30 GPU
cards.
● Not supported.
Single-RAID
or dual-RAID
configuration
(without built-
in drive
modules)
● All CPU
specifications
are supported.
● The rear I/O
modules are
configured with
HDDs and NVMe
drives.
● The rear I/O
modules are
configured with
A2 and A30 GPU
cards.
● All CPU
specifications
are supported.
● When the CPUs
with TDP less
than 270 W are
configured on
the server, the
rear I/O modules
are configured
with A30 GPU
cards.
● Not supported.
FusionServer 5288 V7 Server
Technical White Paper
A Appendix
Issue 01 (2023-07-20)
Copyright © xFusion Digital Technologies Co., Ltd.
126