Network Connectivity
Xerox
®
WorkCentre
®
7800/7800i Series Color Multifunction Printer
61
System Administrator Guide
Configuring Raw TCP/IP Advanced Settings
1.
On the Raw TCP/IP Printing page, click the
Advanced
tab.
2.
Under Connections, set the following:
−
Set the Maximum Connections per port between
1–32
. The default port value is 32.
−
To allow concurrent jobs to process for each port connection, type a number between
0–500
jobs in each port. Type
0
to allow unlimited concurrent jobs.
−
To limit the number of jobs that are active for each port connection, type a number between
0–32768
. Type
0
to allow unlimited number of active jobs.
3.
Under Job Boundary Determination:
−
Type the End of Job Timeout between
0–1800
seconds to specify the amount of time to pass
before a job processes with an End of Job character. The default time is 300 seconds. Type
0
to
disable end of job detection by timeout.
4.
Under Backchannel Data:
−
Enable
Backchannel Data Transmission to Client
, then, enable
Out of Order Backchannel
Data
to allow data from several jobs to be interspersed.
Note:
Out of Order Backchannel Data is only available when Backchannel Data Transmission to
Client is enabled.
5.
Under Banner Page Printing:
−
To restrict banner pages to print for specific jobs only, select the job types from the Banner
Page Enabled drop-down menu. Options are
First Job Only
,
No Jobs
, or
All Jobs
.
−
To enable banner pages to print before each PDL document within a single job, select
Enabled
for Banner Page for Each Document of Job.
−
To restrict banner pages to print for jobs that specifically request them through PJL, select
Enabled
for Banner Page for Job Containing only PJL Commands.
6.
Miscellaneous
−
To allow the printer to switch between multiple PDLs within a single job, select
Enabled
for
Language (PDL) Switching within PJL Job.
−
To force parsing of job data, select
Enabled
for Job Data Parsing Override.
Note:
Job data is not parsed when bidirectional communication and PDL switching are disabled.
7.
Click
Apply
to save the new settings or
Undo
to retain the previous settings.
Click
Default All
to reset settings to default values.