Solution
• On the User Interface, press the
Home
button, and check the status of the
CRUs/Supplies
.
Shake or replace the affected dry ink/toner cartridge. Refer to
.
• For suggested solutions, refer to
Custom Paper Settings Troubleshooting
• Determine if a drum cartridge is contaminated or light-shocked by running a set of halftone
test patterns to identify which color is affected:
–
Go to
and download the
Halftone Test Pattern
PDF.
–
Print several sets of the
Halftone Test Pattern
. PDF.
–
Identify which color is affected.
–
Replace or swap the appropriate drum. Refer to
.
• For other suggested solutions, refer to
Custom Paper Settings Troubleshooting
.
IIm
maaggee--oonn--PPaappeerr RReeggiissttrraattiioonn
Problem
The entire image on the printed output is misregistered, shifted, skewed or crooked.