REP 3.1 Scan Position Sensor
(continued)
Replacement
1. Connect J405.
2. Reinstall scan position sensor on scan
sensor bracket.
3. Position the sensor actuator in cutout on
upper scan frame.
4. Reinstall scan sensor bracket.
5. Route wires around guide fingers and
cutout on retard stop bracket and
through cable clamp (Figure 1).
6. Reinstall remaining components in
reverse order.
REP 3.2 Scan Interlock Switch
Parts List on PL 3.1
Removal
1. Remove power cord.
2. Remove document catch tray assembly
(REP 1.1).
3. Remove RH cover (REP 1.2).
4. Remove coupler cover (REP 1.3).
5. Remove LH cover (REP 1.4).
6. If installed, remove A8 store & forward
PWB (REP 5.4).
7. Remove A2 main PWB (REP 5.5).
8. Remove power supply assembly (REP 5.6).
9. Remove CNC PWB assembly (REP 5.10).
10. Remove scan interlock switch.
a.
Remove scan interlock switch harness
from cable clamp.
b.
Remove screw securing scan interlock
switch.
c.
Remove scan interlock switch.
Replacement
1. Reposition scan interlock switch on
locating point and to the rear of the tab
on the LH frame.
2. Reinstall screw securing scan interlock
switch.
CAUTION
Position scan interlock switch harness away
from scan output drive belt.
3. Reinstall scan interlock switch harness in
cable clamp.
4. Reinstall remaining components in
reverse order.
12/88
REP 3.1, 3.2
4-16
Telecopier 7017 / 7017SF
www.printcopy.info
www.printcopy.info
Содержание Telecopier 7017
Страница 35: ...IQ 1 6 Modem Noise 12 88 Telecopier 7017 7017SF 3 9 IQ 1 6 www printcopy info w w w p r i n t c o p y i n f o...
Страница 172: ...6 88 Plug Jack Locational 7 4 Telecopier 7017 7017SF www printcopy info w w w p r i n t c o p y i n f o...
Страница 173: ...8 88 Telecopier 7017 7017SF 7 5 Plug Jack Locationals www printcopy info w w w p r i n t c o p y i n f o...