N I C M I B D e f i n i t i o n
C-8
❖
D o c u P r i n t 4 5 1 2 / 4 5 1 2 N N e t w o r k I n t e r f a c e C a r d U s e r G u i d e
::= { portcapEntry 5 }
NIC response is N/A
portsojdelay OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..5))
ACCESS read-write
STATUS mandatory
DESCRIPTION
This variable specifies the start of job delay in seconds for the port specified by
portindex."
::= { portcapEntry 6 }
NIC response is N/A
porteoj OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable specifies the end of job string for the port specified by portindex."
::= { portcapEntry 7 }
NIC response is N/A
porteojdelay OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..5))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable specifies the delay between the end of job and the end of job string for the
port specified by portindex."
::= { portcapEntry 8 }
NIC response is N/A
portstrobe OBJECT-TYPE
SYNTAX DisplayString (SIZE(2..3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable specifies the amount of time in microseconds the strobe is kept active for
each character. The string is translated into a value understood by the firmware. The valid
strings are: "
::= { portcapEntry 9 }
NIC response is N/A
mioblocksize OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..5))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable specifies the data transfer block size used by MIO interface cards."
::= { portcapEntry 10 }
NIC response is N/A
portbaud OBJECT-TYPE
SYNTAX DisplayString (SIZE(3..6))
ACCESS read-write
STATUS mandatory
DESCRIPTION
Book.frm : APPC.FRM Page 8 Saturday, October 12, 1996 7:43 AM