Resolute User Manual Version 2.5
30
be set higher than the disconnect voltage of the LVD. The restart voltage must be set with the
“setrestartvoltage [voltage]” command. This should be set a few hundred millivolts above the
shutdown voltage. The default restart voltage is 11.7 V. The three commands required to
configure the shutdown voltage are shown for a shutdown voltage of 10.5 V and a restart voltage
of 10.8V.
$SetShutdownVoltageEnabled t
$SetShutdownVoltage 10.5
$SetRestartVoltage 10.8