Cell SIM Inserted on Cell modem (4)
Installing Power to the Unit
The Resolute requires power supply capable of sourcing three amp surge currents at 12 V. this
can be reduced to one amp if no Iridium or Cellular modem is present. The power cable supplied
has a red ring that matches the red ring of the power connector on the box.
outlines
average power consumption requirements for various configurations of the Resolute.
The majority of units in the field will be powered by battery and solar panel. It is recommended
to utilize a charge controller for your battery equipped with a low voltage disconnect. This will
increase the lifespan of your battery.
It is also important to ground the Resolute for lightning and surge protection. The ground stud is
located to the left of the serial connector and is pictured below. The thread of the grounding stud
is 2 BA
2 BA Threaded Ground Stud