SPC
I Co
mmand T
ree
975-0200
-01-01
A-17
A
Set
(Immediate)
Voltage Set
point
[[:]SOURce[<channel>]]:VOLTage[:LEVel]
[:IMMediate][:AMPLitude]
Change voltage set point
(immediate)
?|<Voltage Set
Point>|MAXimum|
MINimum
Yes
Set Over
Voltage
Protection
Level
[[:]SOURce[<channel>]]:VOLTage:PROTect
ion[:OVERvoltage][:LEVel]
Set the over voltage
protection level.
?|<OVP Set
Point>|MAXimum|
MINimum
Yes
Set Under
Voltage
Protection
Level
[[:]SOURce[<channel>]]:VOLTage:PROTect
ion:UNDer[:LEVel]
Set the under voltage
protection level.
?|<UVP Set
Point>|MAXimum|
MINimum
Yes
Table A-3
SCPI Commands for Output Control (Continued)
Содержание XTR 100-17