SCPI Command Reference
A-6
975-0200-01-01
Terminating Characters
Every command string must end with a terminating <new line> character.
It is also acceptable to use a <carriage return> followed by a <new line>.
Terminating a command string always resets the SCPI command path to
the root level.
Common Commands
The IEEE-488.2 standard includes a set of common commands for
functions such as reset and self-test. These common commands always
start with an asterisk (*), contain 4 or 5 characters, and may have one or
more parameters. The command is always separated from the parameter
by a blank space. Multiple commands sent in the same string are
separated by a semi-colon (;). The following is an example of how 3
common commands can be sent together in the same string:
*OPC; *PSC Off; *TRG
Parameter Types
Several different data types are defined for use in program messages and
response messages.
Boolean Parameters
Boolean parameters are single binary conditions such as 1 and 0, or ON
and OFF. The following is an example of a command that uses Boolean
parameters:
SYST:COMM:GPIB:PONS {ON|OFF|1|0}
Discrete Parameters
Discrete parameters are used when program settings have a limited
number of values. If you query a discrete parameter, the response will
always be in the short form with all uppercase letters. The following is an
example of a command that uses discrete parameters:
TRIG:SOUR {BUS|EXT|IMM|NONE}
Содержание XTR 100-17
Страница 2: ......
Страница 3: ...XTR 850 Watt and 1700 Watt Series Programmable DC Power Supply Operating Manual...
Страница 6: ......
Страница 18: ...xvi...
Страница 48: ...2 18...
Страница 86: ...Local Operation 3 38 975 0200 01 01 Figure 3 4 Split Supply Operation V V Common Power Supply Power Supply Load...
Страница 122: ...4 30...
Страница 208: ...6 20...
Страница 244: ...A 36...
Страница 250: ...B 6...
Страница 264: ...C 14...
Страница 272: ...IX 4...
Страница 273: ......