A-34 975-0200-01-01
S
C
PI
C
o
mm
an
d
R
e
fe
re
n
ce
Table A-11
Protection Commands
Function
SCPI Command
Description
Parameter and
Range
Query
Enable the
interlock
functionality.
[:]SENSe[<channel>]:PROTection
:INTerlock[:STATe]
Control the Enable/Disable
state of the Interlock
System.
?|ON|OFF
Yes
Table A-12
Auto Sequence Commands
Function
SCPI Command
Description
Parameter and Range Query
Delete all
sequences.
[:]PROGram[<channel>]:DELete:ALL
Erases the sequence
currently in memory.
N/A
Change Auto
Sequence
operating
state.
[:]PROGram[<channel>]:STATe
Access to the run state of
the Sequence.
?|RUN|STOP|PAUSE
Yes
Program
selected
sequence end
action.
[:]PROGram[<channel>]:REPeaT
Sets the number of times
to repeat the sequence.
?|<Repeat count (1–
65534)>INFinity
Yes
Begin
Recording
Auto
Sequence
Program
[:]PROGram[<channel>][:RECord]:STARt
Start recording new
sequence (overwrites old
sequence).
N/A
Stop
Recording
Auto
Sequence
Program
[:]PROGram[<channel>][:RECord]:STOP
Stop recording the auto
sequence program.
(Sequence ready to run.)
N/A
Содержание XTR 100-17
Страница 2: ......
Страница 3: ...XTR 850 Watt and 1700 Watt Series Programmable DC Power Supply Operating Manual...
Страница 6: ......
Страница 18: ...xvi...
Страница 48: ...2 18...
Страница 86: ...Local Operation 3 38 975 0200 01 01 Figure 3 4 Split Supply Operation V V Common Power Supply Power Supply Load...
Страница 122: ...4 30...
Страница 208: ...6 20...
Страница 244: ...A 36...
Страница 250: ...B 6...
Страница 264: ...C 14...
Страница 272: ...IX 4...
Страница 273: ......