975-0200-01-01
C-7
Common Speci
fications for All M
o
del
s
C
Common Specifications for All Models
Output Voltage and Current Monitor
0–100%, 2~ up to 10 V, programmable
On/Off Control
TTL level
AUX On/Off Control
TTL level or dry contact
Power Supply Status Signal
TTL high: OK
TTL low: fail
Interlock Enable/Disable
Dry contact. Open/Short: On or Off,
programmable
Output Performance Specifications
Temperature Coefficient
100 PPM/° C from rated output voltage, after a 30-minute warm-up
Drift (8 hours)
0.05% of rated output (over an 8 hour interval with constant line, load and temperature, after a 30-minute warm-up)
Hold-up Time
Typical 20 ms at any rated input line.
Transient Response Time
1
1.Time for the output voltage to recover within 0.5% at its rated output for a load change 10–90% of rated output current. Output set point
10–100%.
Less than 1 ms for 6 V to 60 V models. Less than 2 ms for 80 V to 600 V models
Meter Accuracy
0.5% ± 1 count
Isolation
AC Input to Output
AC Input to Chassis
Output to Chassis
1350 Vac
1350 Vac
500 Vac
Table C-3
Remote Operation
Programming Mode
APG
ISOL
Digital
Содержание XTR 100-17
Страница 2: ......
Страница 3: ...XTR 850 Watt and 1700 Watt Series Programmable DC Power Supply Operating Manual...
Страница 6: ......
Страница 18: ...xvi...
Страница 48: ...2 18...
Страница 86: ...Local Operation 3 38 975 0200 01 01 Figure 3 4 Split Supply Operation V V Common Power Supply Power Supply Load...
Страница 122: ...4 30...
Страница 208: ...6 20...
Страница 244: ...A 36...
Страница 250: ...B 6...
Страница 264: ...C 14...
Страница 272: ...IX 4...
Страница 273: ......