62
Freedom SW Installation Guide
Specifications
NOTE
: All transfer specifications are at nominal conditions: ambient temperature of 77 °F (25 °C), 120 VAC, 60 Hz input, unless otherwise specified.
Transfer and General Specifications
All Models
Transfer time—utility to invert
< 20 ms
Minimum AC input voltage for transfer
85 VAC RMS
Maximum AC input voltage for transfer
135 VAC RMS
Minimum AC input frequency for transfer
45 Hz
Maximum AC input frequency for transfer
70 Hz
Cooling
Fan-cooled, temperature controlled.
Regulatory Approvals
All Models
Safety
CSA 107.1,
UL 458 with marine supplement,
ABYC E11 - Alternating Current and Direct Current Electrical Systems on Boats, and
ABYC A31 - Battery Chargers and Inverters.
EMC
FCC Part 15, Class B
Industry Canada ICES-0003, Class B
Freedom SW 3K2K InvChg Install Guide.book Page 62 Wednesday, October 12, 2011 4:40 PM