background image

User manual

ADA-7010D

Multimode Fibre-Optic to RS-232 Digital Converter

1

io_ada-7010d_en_v3.20

ADA-7010D

Copyright © 2001-2017 CEL-MAR sp.j.

Summary of Contents for ADA-7010D

Page 1: ...User manual ADA 7010D Multimode Fibre Optic to RS 232 Digital Converter 1 io_ada 7010d_en_v3 20 ADA 7010D Copyright 2001 2017 CEL MAR sp j ...

Page 2: ...5 4 INSTALLATION 6 4 1 ASSEMBLING 6 4 2 CONNECTION TO DEVICE WITH RS232 INTERFACE 6 4 3 CONNECTION FIBRE OPTIC BUS 6 4 4 POWER SUPPLY CONNECTION 7 5 ACTIVATION 7 6 CONFIGURATION 8 6 1 HARDWARE CONFIGURATION 8 6 1 1 OPERATION MODE 8 6 2 CONNECTION TO PC 8 6 3 CONFIGURATION BY USING ADACONFIG 8 6 4 DATA TRANSMISSION DIAGNOSTICS 9 6 5 FIRMWARE UPDATE 9 6 6 EMERGENCY FIRMWARE UPDATE 10 6 7 FACTORY DEF...

Page 3: ... is only after disconnecting the power supply circuit voltage Do not carry out the assembly or dis assembly of the device if it is enabled This may result to short circuit and damage the device The device can not be used for applications that determine human life and health eg Medical ATTENTION The device is equipped in the laser transmitter The radiation emitted by the laser transmitter is harmfu...

Page 4: ...out the state of RS232 line ADA 7010D converter can configure the baud rate number of data bits even parity or not and the number of stop bits The settings apply to the RS232 interface and can be different on both sides of the fiber optic Using multimode fiber provides complete isolation between connected devices and resistance to interference on the transmission line The fiber optic connection is...

Page 5: ...re 4 possibilities of use ADA 7010D like extender of RS232 PC port Fig 3 Operating principle of the converter ADA 7010D Fig 4 Example connection of cash register with RS232 interface distanced of 2500m to PC by the use of ADA 7010D 5 ADA 7010D Power Supply 10 30VDC Fiber Optic RS232 ISOLATION PC SG 5 DB 9M plug CTS 8 RTS 7 DSR 6 DTR 4 TxD 3 RxD 2 ADA 7010D GND RS232 connector RTS CTS DTR DSR Rx Tx...

Page 6: ...l converter should mount device on the rail upper part of the case then press bottom part to hearing characteristic Click sound 4 2 CONNECTION TO DEVICE WITH RS232 INTERFACE In the purpose of connecting ADA 7010D to device with RS232 port DTE type eg computer connection should be done as follows Fig 5 Example connection of ADA 7010D to RS 232 port of PC 4 3 CONNECTION FIBRE OPTIC BUS The multimode...

Page 7: ...k at a frequency of 10Hz up to remove the irregularities Should be remembered that once this is fixed should wait about 5 seconds to synchronize the two converters the LED will be OFF During data transmission via ADA 7010D should blink LEDs Description of signalling LEDs are shown in the table below LED Description PWR Signalling of Power Supply Run mode TX Data transmission from ADA 7010D via RS ...

Page 8: ...3 CONFIGURATION BY USING ADACONFIG The configuration of ADA 7010D converter can be made by the use of ADAConfig Software selling with converter To make the configuration connect converter to computer and power supply If after power on the front panel is not lit green LED PWR check the power connection polarity If the PWR LED lights set the section of SW1 switch to configuration mode as in table be...

Page 9: ...r press Delete transmission errors In case of parity errors or frame errors should be checked the ADA 7010D converter s configuration and correctness connection of RS232 interface and to Fibre Optic converter port After finishing the diagnostics the SW1 microswitch should be set to the run mode see pt OPERATION MODE 6 5 FIRMWARE UPDATE Set SW1 microswitch to configuration mode as in table below SW...

Page 10: ... mode as in the table below SW1 1 SW1 2 ON ON After micro switch setting ADA 7010D should be restarted by turning OFF and then ON the power supply The yellow LED will light continuously and the converter will be in Emergency Firmware Update mode Now follow the description in point FIRMWARE UPDATE After successful updating set SW1 micro switch as in table below Yellow LED will be OFF SW1 1 SW1 2 OF...

Page 11: ...over without inlets plug in screw terminal block 1 ST type 850nm fibre connectors S standard operating temperature range from 0 C up to 50 C Galvanic isolation 1kV 2 3kV 3 Terminal Terminal Cover Cover without inlets screw terminal block 1 Cover with inlets screw terminal block 2 Cover without inlets plug in screw terminal block 3 Fibre connectors ST type 850nm 1 SC type 850nm 2 SMA type 650nm 3 O...

Page 12: ...mmercial and light industrial Environmental Parameters Operating temperature Standard version S 0 C 23 C 50 C Extended version E 35 C 23 C 60 C Humidity 5 95 non condensing Storage temperature 40 70 C Casing Dimensions 53 x 90 x 58mm Material Noryl UL 94 V O Degree of casing protection IP40 Degree of terminal protection IP20 Weight 0 10 kg According to standards DIN EN50022 DIN EN43880 Location du...

Reviews: