Environmental Specifications
975-0998-01-01
47
Freedom EX 4000
Nominal voltage
48 VDC
Operating voltage
40–64 VDC
Maximum current at full load
130 ADC
Table 11 DC input for inverting
Freedom EX 4000
Nominal voltage
48 VDC
Maximum voltage
64 VDC
Maximum charge rate
80 A single unit
160 A when parallel or
series stacked
f
Power factor corrected charging
PF (0.98)
Table 12 DC output for charging
Freedom EX 4000
Nominal output voltage
13.5 VDC
Maximum output current
45A (continuous @
25 °C ambient)
50A (15 minutes @
25 °C ambient)
70A (6 minutes @ 25 °C
ambient)
Table 13 DC output for 12 VDC load
Freedom EX 4000
Output voltage options
105 to 130 VAC
Continuous power (W
g
)
4000 W @ 40 °C with
output derated above
104 ºF (40 °C)
Continuous current
33.3 A
Surge power (5 sec)
8000 W
Output Frequency
60 Hz
GFCI protection
h
customer-provided
Wave shape
True Sine Wave
Total Harmonic Distortion
< 5% at rated power
Table 14 AC output for inverting
f
Contact Xantrex prior to stacking two Freedom EX 4000 units together. Stacking configuration via USB
is a required step to enable stacking.
g
Power derates to 85% when output voltage is set to 110/108 VAC.
h
See
Ground Fault Circuit Interrupters (GFCIs) on page 14
for approved device/s.
Freedom EX 4000
Output voltage options
210 to 260 VAC
Continuous current
33.3 A
Surge power (5 sec)
16000 W
Output Frequency
60 Hz
Table 15 AC output for series-stacked
i
pair inverters
Freedom EX 4000
Output voltage options
105 to 130 VAC
Continuous current
66.6 A
Surge power (5 sec)
16000 W
Output Frequency
60 Hz
Table 16 AC output for parallel-stacked
j
pair inverters
Freedom EX 4000
Input voltage single-phase (L1-N and
L2-N)
80–138 VAC [(120 V
nominal), default range]
60–155 VAC [(120 V
nominal), allowable
range]
Input voltage split-phase
k
(L1-L2)
160–276 VAC
Input breaker
50A, double-pole
Input frequency range
54.5–65 Hz (default)
44–68 Hz (allowable)
Peak efficiency
91%
Full load efficiency
≥
86%
Table 17 AC input for charging and pass-through
Product Number
BTS (battery temperature sensor)
808-0232-01
Network terminator
809-0901
Ferrite core
023-0189-01
Remote panel
808-0817-03
20-pin harness
808-0820
Drip shield
808-9004
Table 18 Accessories
NOTE
: Contact Xantrex or your dealer to order these
accessories.
i
Contact Xantrex prior to stacking two Freedom EX 4000 units together. Stacking configuration via USB
is a required step to enable stacking.
j
Contact Xantrex prior to stacking two Freedom EX 4000 units together. Stacking configuration via USB
is a required step to enable stacking.
k
L1-N must be within the single-phase qualification voltage range, 80–138 VAC, for split-phase to
operate in a split-phase configuration.