Basic Installation Procedures
975-0998-01-01
41
Step 8: Battery Configuration
After all wiring is done, the next major step is to configure the
battery type.
1. Switch open the battery's DC breaker to disconnect DC
power. In a Stacking configuration with two
inverter/chargers, switch open the single 2-pole battery
breaker to disconnect DC power.
2. Close the input and output AC circuit breakers on the
vehicle's AC load distribution panel. This will allow AC
shore power to pass-through and energize the Freedom
EX 4000.
3. Observe the green AC source LED
on the top panel. It
should turn on and remain steady.
OUTPUTBATTLOAD
kW
100%
25%
Hz
VA
%
kW
Hz
VA
%C
INPUTBATTTEMP
AC
BYPASS
ERROR
OVERLOAD
CHARGING
5s
a
b
c
d
e
f
g
4. Configure the Battery Type using the Remote Panel.
a. Press the Power button.
b. Press and hold the OK button for 5 seconds until
ESC starts flashing on the screen.
c. Press the Scroll button to browse through the
different settings until you get to "20" which is the
Battery Type setting.
d. Press the OK button to confirm.
e. Press the Scroll button to browse through the
different battery types until you get to the
corresponding battery type of your house battery.
f. Press the OK button to confirm the selection.
g. Press the ESC button to exit configuration.
5. Switch open the input and output AC circuit breakers to
disconnect shore power.
Step 9: Testing Your Installation
WARNING
ELECTRIC SHOCK HAZARD
Pressing the Power button to turn the Freedom EX 4000 inverter
to Standby on the display panel does not disconnect DC or AC
input power to the Freedom EX 4000. If shore power is present at
AC input terminals, it will pass through to the AC output.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
There are two tests to be performed. The first test verifies that
the Freedom EX 4000 is inverting DC battery power and
delivering AC power to its output.
The second test is intended for installations where AC input and
output is hard wired to the Freedom EX 4000. This test verifies
that the Freedom EX 4000 transfers from inverter power to
shore power when shore power is present.
NOTE
: Shore power (pass-through) refers to the AC input power
from a utility grid, generator or external AC source.
When you are ready to test your installation and operate the
Freedom EX 4000, close the DC fuse and Disconnect or the DC
circuit breaker to supply DC power to the Freedom EX 4000.
Testing in Battery Mode
To test the Freedom EX 4000:
1. For hard wired installations, ensure shore power is not
present. Open the input AC breakers.
2. Close the battery disconnect device (or the 2-pole battery
breaker if in Stacking configuration) to energize the
inverter/charger with battery power.
3. Press the Power button to turn the
inverter/charger/converter on.
4. Plug a test load, such as a lamp within the power rating of
the inverter/charger/converter into an AC outlet
downstream from the AC distribution panel
5. Turn the lamp on to verify that it operates.
If the lamp operates, your installation is successful. If your
installation has AC input and output hard wired to the Freedom
EX 4000, proceed to
.
If the status LED on the display panel glows red, see the
Troubleshooting chapter.