Marine Installation
975-0998-01-01
43
Marine Installation
Figure 32 Typical Marine Installation
7
a
b
9
8
3
5
4
6
2
1
12
11
10
50A
1
Communications and Control 20-pin Harness
2
Freedom EX 4000
3
Equipment ground – Engine negative bus / DC ground bus
4
DC fuse/disconnect/DC circuit breaker
5
48V deep cycle battery bank and protected by a DC fuse in the positive cable
6
Equipment ground – DC ground bus
7
AC inverter load panel with AC-rated SPD/TVSS (a) and branch circuit breakers that
supply only loads that run off the Freedom EX 4000
8
AC source shore panel that includes a max 50A breaker
IMPORTANT
To the installer: Affix the provided safety label to the source panel where the Freedom EX
4000 will be connected to.
9
Shore power receptacle – AC power supplied from a shore power connector
10
Vessel dogbone adapter and/or power extension cord
11
Dock site power panel with electrical receptacles
12
Fused 12VDC load sub-panel with a DC-rated SPD/TVSS (b)
ac
DO NOT CONNECT DC LOAD SUB-PANEL NEG(-) TO DC ground bus.
NOTE
: The NEG(-) 48V and 12V are bonded internally.
Содержание Freedom EX 4000
Страница 8: ...This page is intentionally left blank 2...
Страница 10: ...This page is intentionally left blank 1...
Страница 51: ...This page is intentionally left blank 2...