Basic Installation Procedures
42
Freedom EX 4000 Installation Guide
Testing in Shore Mode
To test the Freedom EX 4000:
n
With the test load from the previous test still connected
and operating, connect the shore power source.
n
The Freedom EX 4000 transfers the test load to shore
power. The green LED indicating shore mode turns on.
n
If the test load operates, your installation is successful.
NOTE
: If the Power button on the Freedom EX 4000 is turned
ON, the Freedom EX 4000 will automatically supply the
appliances with inverter power if the shore power source fails or
becomes disconnected.
If the Power button on the Freedom EX 4000 is turned ON and
shore power voltage is too low (less than 80 VAC
1
), the unit will
transfer to inverter power to continue running your appliances.
NOTE
: Whether or not the Power button is turned ON, shore
power will pass through the Freedom EX 4000 to the output
when shore power is within normal operating range. When
charging is enabled, the unit also starts charging the battery
after the transfer to shore mode.
NOTE
: In the event of low or no battery voltage, shore power
will pass through the Freedom EX 4000 to the output even when
shore power is outside the normal operating range and battery
DC terminals will rise to a voltage proportional to AC input
voltage (42VDC at nominal, 120VAC input).
1