8.2 BAT Warning Codes
Table 10: Extract of BAT Warning Codes
Code Warning Description
Corrective Action
12
temperature_high_L1
Reduce power/check cooling
14
temperature_high_L2
Reduce power/check cooling
16
temperature_high_L3
Reduce power/check cooling
17
temperature_high_PT100_X108A12 Reduce power/check cooling
18
temperature_high_PT100_X108A34 Reduce power/check cooling
19
temperature_high_PT100_X108B12 Reduce power/check cooling
20
temperature_high_PT100_X108B34 Reduce power/check cooling
21
temperature_high_board
Reduce power/check cooling
22
temperature_low_L1
Check heating
23
temperature_low_L2
Check heating
24
temperature_low_L3
Check heating
25
temperature_low_PT100_X108A12
Check heating
26
temperature_low_PT100_X108A34
Check heating
27
temperature_low_PT100_X108B12
Check heating
28
temperature_low_PT100_X108B34
Check heating
29
temperature_low_board
Check heating
170
Overvoltage protection fault
Check OV protection and filter
fuses
8.2.1 BAT Warning Codes 12, 14, 16, 17-21
Corrective action:
1.
See
Section 8.1.1.
8.2.2 BAT Warning Codes 22-29
Corrective action:
1.
See
Section 8.1.3.
8.2.3 BAT Warning Code 170
Corrective action:
1.
See
Section 8.1.8.
Содержание BATD0100-ES-1-480-1