ESC # m n data
Function:
Transmit Data to Sub-device (Customer Display)
Code:
<1B>H <23>H <m> <n> (<p>)n
Range:
m = 0
0
≤
n
≤
255
0
≤
p
≤
255
Description:
With this command, the following n bytes are transmitted to the sub-
channel. The ND69 has only the sub-channel 0, which is the V.24
interface for connection to the customer display.
The data transmission is transparent, i.e. the n bytes can have arbitrary
values, which means they may also contain control commands (for the
customer display).
Remarks:
No data are transmitted from the customer display to the host
computer. After switching on, the customer display transmits data (ID).
These can be printed during the self test.
ESC p m n1 n2
Function:
Open Cash Drawer Cover
Code:
<1B>H <70>H <m> <n1> <n2>
Range:
m = 0 or 1
0
≤
n1
≤
255
0
≤
n2
≤
255
Description:
The opening impulse defined by n1 and n2 is transmitted to the
selected cash drawer.
m = 0:
Open first cash drawer,
m = 1:
Open second cash drawer.
n1 * 10ms
is the duration of the opening impulse;
n2 * 10ms
is the minimum period between two impulses to the same
cash drawer.
n1 = 5 and n2 = 255 are required for WN cash drawers.
Description
Control Sequences