LCD Data Area
When LCD ON, the indirect RAM area EEH
−
FFH work as the LCD data RAM (LCD00
−
LCD35).
Instruction such as "MOV @R0, #I" (Where R0 = EEH
−
FFH) are used to control the LCD data RAM.
The data in the LCD data RAM (bit7
−
bit0) are transferred to the segment output pins automatically
without program control. When the bit value of the LCD data RAM is "1", the LCD is turned on. When
the bit value of the LCD data RAM is "0", LCD is turned off. The relation between the LCD data RAM
and segment/common pins is shows below.
LCD
COM3
COM2 COM1 COM0
COM3
COM2 COM1 COM0
Data RAM
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
EEH
SEG1
SEG0
EFH
SEG3
SEG2
F0H
SEG5
SEG4
F1H
SEG7
SEG6
F2H
SEG9
SEG8
F3H
SEG11
SEG10
F4H
SEG13
SEG12
F5H
SEG15
SEG14
F6H
SEG17
SEG16
F7H
SEG19
SEG18
F8H
SEG21
SEG20
F9H
SEG23
SEG22
FAH
SEG25
SEG24
FBH
SEG27
SEG26
FCH
SEG29
SEG28
FFH
SEG35