![WIKA IPT-2 Series Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/wika/ipt-2-series/ipt-2-series_operating-instructions-manual_980233056.webp)
56
9 Supplement
WIKA Operating Instructions - Process pressure transmitter IPT-2x
Process conditions - Ceramic/metallic measuring cell
Process temperature
Version
Temperature range
p
abs
≥ 50 mbar
p
abs
≥ 10 mbar
p
abs
≥ 1 mbar
Standard
-12 … +150 °C (+10 … +284 °F)
-12 … +120 °C
(+10 … +248 °F)
Extended temperature
range
-12 … +180 °C
(+10 … +356 °F)
-12 … +160 °C
(+10 … +320 °F)
-12 … +200 °C
(+10 … +392 °F)
Temperature derating
1
2
0 °C
(32 °F)
60 °C
(140 °F)
80 °C
(176 °F)
150 °C
(302 °F)
110 °C
(230 °F)
Fig. 31: Temperature derating IPT-2x, version up to +150 °C (+302 °F)
1 Process temperature
2 Ambient temperature
1
2
0 °C
(32 °F)
65 °C
(149 °F)
80 °C
(176 °F)
180 °C
(356 °F)
150 °C
(302 °F)
Fig. 32: Temperature derating IPT-2x, version up to +180 °C (+356 °F)
1 Process temperature
2 Ambient temperature