![WIKA IPT-2 Series Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/wika/ipt-2-series/ipt-2-series_operating-instructions-manual_980233041.webp)
41
6 Set up with the display and adjustment module
WIKA Operating Instructions - Process pressure transmitter IPT-2x
6.1.4 Additional adjustments
In menu item "
Current output, variable
" you specify which measured
variable is output via the current output.
The following selection is possible depending on the selected ap-
plication:
•
Flow
•
Height - Interface
•
Density
•
Differential pressure
•
Static pressure
•
Percent
•
Scaled
•
Percent linearized
•
Measuring cell temperature (ceramic measuring cell)
•
Electronics temperature
In this menu item, the units for the DP flow element are determined
and the selection of mass or volume flow is carried out.
Furthermore the adjustment for the volume or mass flow at 0 % or
100 % is carried out.
The device automatically adds the flow in the selected unit. With
appropriate adjustment and bidirectional linearization, the flow rate is
counted both positively and negatively.
Current output 1 and 2
(size)
Characteristics values DP
flow element