Kunststoffschweißtechnik
Starting and Operating
Chapter 5
19.09.11
Working Instructions WIDOS 5500 CNC 3.0
Page 36 of 78
Display:
2. line:
length of 2. pipe
+000.00 mm
Enter the length of the last (read in) barcode pipe 2 up to the joint by
buttons <+ / - / Enter>
Press button <Start>
Display:
2
nd
line:
mat diam wall temp
PE80 225 20.5 206°
The welding parameters are displayed
next menu by pressing <Start> button
Continue as described in chapter 5.11, welding process
.
5.12. Error Messages
If during the work with the machine
•
the prescriptions of the DVS are not followed
•
the working steps necessary for the welding processs are not correctly or not at all
performed
•
certain measuring devices do not funtion,
the following error messages will appear on the display:
T
Heating element temperature
A
Adjusting
W
Heating
U
Change over
R
Pressure build-up ramp
t
Joining time
p
Joining pressure
In case of an error, these error codes will also appear in the first line of the display.
All error messages are logged.
5.13. Administration of the Welding Data
The battery-buffered CNC memory (RAM) can store about 400 weldings.
Make sure not to go over this quantity (in the display the error message
"memory full“ appears) because otherwise the first stored welding will be over-
written.
If necessary, read the welding data out in time.