Kunststoffschweißtechnik
Equipment care/Maintenance/Repair
Chapter 7
19.09.11
Working Instructions WIDOS 5500 CNC 3.0
Page 50 of 78
7.10. Fuse for Overload Safety Device / Printer Plug Box
The control unit does
not
function although
the control unit is connected to the power
supply, the main switch is on, and the
Emergency-Stop has
not
been pressed and
locked.
In this case the fuse (overload protection)
must be checked.
For this purpose unscrew the right-hand
cover plate, check the fuse (F1) and switch it
on again, if necessary.
7.11. Disposal
At the end of their life time, the machine and the wear parts have to be disposed
of properly and non-polluting, and in accordance with the national laws of waste
disposal.
Fuse (F1)