Troubleshooting
StockSAVER manual - Software version 2.1
80
8.4
Sensor problems
Error
Cause
Solution
Sensors not reacting
LED on the sensor does not
light up
Sensor wiring: Plugs
incorrectly assembled or
broken cable
Check the plug wiring and
rewire if necessary
Sensor does not detect bins
Tilt angle incorrect or
reacting to reflections
from shelving rails above
Adjust the sensor tilt angle
Sensor detects bins although
no bins have been loaded in
the Location
Tilt angle incorrect or
reacting to reflections
from shelving rails above
Adjust the sensor tilt angle
Sensor reports status changes
which haven’t occurred
Tilt angle incorrect or
reacting to reflections
from shelving rails above
Adjust the sensor tilt angle
LED on the sensor does not
light up
Sensor not displayed in
software
Sensor failure
Check function and replace if
necessary
8.5
Software setup problems
Error
Cause
Solution
A message appears: "File
cannot be overwritten: Close
the Windows service
Microsoft .NET Framework
NGEN"
Installation was executed
repeatedly at too short an
interval.
Close the service Microsoft
.NET Framework NGEN and
execute the installation
again.
Language xy is not shown in
the list of languages during
installation.
The language files are not
available.
Ensure that the Internet
connection is available and,
if necessary, that the proxy
server is configured correctly.
Contact WERMA support, if
necessary, for further
information on which
language files are available
for your version.
8.6
Software problems
Error
Cause
Solution
Bus wiring between rack and
SmartBox not possible in
software
Rack has already been wired
with another SmartBox and is
displayed greyed out to
indicate it is occupied
Open the bus wiring for the
other SmartBox and cancel
the existing assignment of the
SensorBox to the Location.
The Location can then be
wired to another
SmartBox/SensorBox.