Attaching the hardware to racks
StockSAVER manual - Software version 2.1
36
Option
Action
Deactivate
If the posting confirmation function of the SmartBox is NOT
activated, then a confirmation beep will be heard after correct
replenishment of a Location. If the replenishment was made to
the wrong Location, an error signal will be given by the
SmartBox which will wait until the user confirms that the
placement error has been rectified (by pressing the button on
the SmartBox).
If you choose to activate this function, then the system will check to ensure that the
appropriate firmware version is installed on the Transceiver via which the SmartBox
communicates. If this is not the case, then you will see the following message:
In this case, you must abort the configuration of the SmartBox. The firmware of the relevant
Transceiver must then be updated. The SmartBox can then be configured again.
5.8.4
Connect the SmartBox and Transceiver to the rack
1.
Connect the SmartBox with the SensorBox bus cable.
2.
Connect the SmartBox to the power supply.
3.
Connect the Transceiver to the power supply.
4.
Connect the Transceiver to the Ethernet connection.