29
IOM-161
MODEL: INFLOW™ ACE WITH AI CONTROL™
REV: D
13839 West Bellfort Street, Sugar Land, TX 77498
welker.com
Service Department 281.491.2331
Disassembling the Upper Housing
19.
Unscrew the machine screws from the top cap and carefully remove the top cap from the motor housing (
).
20.
Unscrew the setscrews from the base of the packing gland body (
21.
Unscrew the packing gland body from the outer shaft.
22.
Unscrew the packing gland body from the motor housing, and then carefully remove the packing gland body from the
insertion shaft. Take care not to scratch or otherwise damage the insertion shaft assembly.
23.
Remove the dustcover from the packing gland body.
24.
Loosen the setscrews in the upper and lower lock collars on the external adjustment body, and then remove the lock
collars from the insertion shaft assembly (
). Take care not to misplace the pins that align the lock collars with
the external adjustment body.
Figure 14: External Adjustment Assembly
25.
Carefully slide the external adjustment body off the insertion shaft. Take care not to scratch or otherwise damage the
insertion shaft assembly.
26.
Carefully pull the insertion shaft out through the motor housing.