Figure 3: Lock Collar Diagram
5.
Loosen the jam nut, and then turn the hanger until the opening in the collection head is aligned with the alignment
indicator rod on the lock collar (
). The opening in the collection head should face the direction of product flow
so that the flowing stream will pass through the opening.
Figure 4: D-Style Collection Head Diagram
6.
Tighten the jam nut on the collection head. The tightened jam nut and safety wire will prevent the collection head from
turning.