2.3 Installing the Unit
1.
Close all valves on the inFlow™ ACE.
2.
Secure the inFlow™ ACE to a full port pipeline isolation valve.
For long probes installed horizontally, Welker recommends field installation of bracing support for the outlet end of the probe
to offset the cantilever effect and prevent bending of the shaft. Any bracing or support installed should NOT contact the probe
shaft, as scratching or other damage to the shaft may lead to loss of integrity of the sealing surface.
The vent (drain) outlet on the lubricator body must be pointed down.
If the unit will be inserted using hydraulic fluid, continue to step 3.
If the unit will be inserted using an auxiliary gas, proceed to step 13.
If the unit will be inserted using pipeline product, proceed to step 24.
11
IOM-161
MODEL: INFLOW™ ACE WITH AI CONTROL™
REV: D
13839 West Bellfort Street, Sugar Land, TX 77498
welker.com
Service Department 281.491.2331