10
Document #: LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 – 9/20
Installation
Section 2
Canopy Ventilation Recommendations
NOTE: Hood shown as dimensional for island mount. Size reductions may be possible for wall mount units.
CAPTURE AREA
CAPTURE AREA
78"
(1981 mm)
AFF MAX
120"
(3048 mm)
22"
(559 mm)
18 - 24"
(457 - 609 mm)
22"
(559 mm)
CAPTURE VELOCITY
CAPTURE
VELOCITY
80"
(2032 mm)
12"
(305 mm)
12"
(305 mm)
AFF = Above Finished Floor
NOTE: The drawing shown is a typical installation and is
intended to be a guideline. It is not a rigid specification.
Hood dimensions and the positioning of the hood over the
oven will vary with hood manufacturers.
NOTE: Lincoln can provide oven spec sheets that show
the dimensions of the oven, kW or BTU ratings and other
information that will be useful to both the ventilation hood
supplier and the HVAC contractor.