Document #: LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 – 9/20
Section 2
Installation
Installation Requirements
DANGER
All utility connections and fixtures must be maintained
in accordance with local and national codes.
GAS CODE REQUIREMENTS
DANGER
Conversion of this appliance from one type of gas to
another must only be performed by qualified, licensed,
and authorized installation or service personnel.
Conversion without the proper components may result
in fire or explosion.
n
Warning
A manual shut-off valve must be installed in the gas
supply (service) line upstream of this appliance and in a
position where it can be reached quickly in the event of
an emergency.
Safe and satisfactory operation of this oven depends to a
great extent upon its proper installation, and it should be
installed, as applicable in accordance with the National
Fuel Gas Codes, ANSI Z223.1/NFPA 54, latest version,
manufacturers’ installation instructions, and local municipal
building codes.
1. The oven and its individual shut off valve must be
disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psig (3.45 kPa).
2. The oven must be isolated from the gas supply piping
system by closing its individual manual shutoff valve
during any pressure testing of the gas supply system at
test pressures equal to or less than 1/2 psig (3.45 kPa).
IN MASSACHUSETTS: Installation of this oven must be
performed by a licensed plumber or gas fitter. All such
connections must be in accordance with applicable code
requirements. Refer to “Installation Requirements” section
for specific information.
IN CANADA: The installation of these appliances is to be in
accordance with CSA B.149.1 latest version – Natural Gas
and Propane Installation Code – and/or local codes.
IN AUSTRALIA: To be installed in accordance with AS 5601-
2004 and 4563-2004 Gas Installation Code.
IN SOUTH AFRICA: To be installed in accordance with SANS
10087-1 or SANS 827, as applicable.
NOTE: In the event that verification of pilot flame is needed,
a small mirror may be utilized for verification.
If flexible services are provided, they must meet code
requirements for such installation.
ELECTRICAL CODE REQUIREMENTS
n
Warning
This appliance must be grounded and all field wiring
must conform to all applicable local and national
codes. Refer to rating plate for proper voltage. It is the
responsibility of the end user to provide the disconnect
means to satisfy the authority having jurisdiction.
n
Warning
This equipment must be positioned so that the plug is
accessible unless other means for disconnection from
the power supply (e.g., circuit breaker or disconnect
switch) is provided.
When installed, this appliance must be electrically
grounded and its installation must comply with the
National Electric Code, ANSI-NFPA 70, latest edition, the
manufacturers’ installation instructions, and applicable local
municipal building codes.
IN CANADA: All electrical connections are to be made
in accordance with CSA C22.1 latest version – Canadian
Electrical Code and/or local codes.
ALL OTHER COUNTRIES: Local gas and/or electrical codes
will prevail.
1. Strain Relief is provided with each oven. International
Dealer/Distributors provide applicable power cord/
plug for each customer.
2. All pole disconnection switch must have 3 mm open
contact distance.
3. To prevent electrical shock, an equal potential bonding
ground lug is provided in the back. This allows the oven
to be connected to an external bonding system.
4. If used as double or triple stack and each oven has its
own disconnection switch, all switches should be close
together.
Содержание Lincoln Impinger 1600 Series
Страница 20: ...20 Document LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 9 20 Operation Section 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...44 Document LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 9 20 Charts Section 8 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 49: ...Document LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 9 20 Notes ...
Страница 50: ...50 Document LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 9 20 Notes ...
Страница 51: ...Document LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 9 20 Section 9 Diagrams THIS PAGE INTENTIONALLY LEFT BLANK ...