Document #: LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 – 9/20
Section 8
Charts
Specifications – Models with Gas Heat
Electrical Service – All Models with Gas Heat
Voltage (AC)
Phase
50/60 Hz Ovens
220/230
1
Notice
Do not install the (these) oven(s) in any area with an
ambient temperature in excess of 95°F/35°C. Doing so
will cause damage to the unit(s).
SPECIFICATIONS
BODY: Stainless Steel (Exterior except back panels)
POWER: Gas
DB LEVEL: ≤77 dba
OPERATING TEMPERATURE RANGE: 250° - 600°F
(121° - 316°C)
Gas Ovens
Model*
Energy
Power
Voltage
Current Phase
Hz
Recommended
Electrical Specification
Gas Manifold
Pressure**
1631-xxx-X-Kxxxx
G20
32 kW (HI) 3.35 m
3
/hr
230 VAC
4 Amps
1
50 Hz
3 Wires, 1 Pole 1N-1G
8.7 mB
1631-xxx-X-Kxxxx
G25
26.5 kW (HI) 3.18 m
3
/hr
230 VAC
4 Amps
1
50 Hz
3 Wires, 1 Pole 1N-1G
8.7 mB
1631-xxx-X-Kxxxx
G25.3
26.5 kW (HI) 3.22 m
3
/hr
230 VAC
4 Amps
1
50 Hz
3 Wires, 1 Pole 1N-1G
8.7 mB
1632-xxx-X-Kxxxx
G30
37 kW (HI) 1.16 m
3
/hr
230 VAC
4 Amps
1
50 Hz
3 Wires, 1 Pole 1N-1G
24.8 mB
1632-xxx-X-Kxxxx
G31
33.2 kW (HI) 1.33 m
3
/hr
230 VAC
4 Amps
1
50 Hz
3 Wires, 1 Pole 1N-1G
24.8 mB
1633-xxx-X-Kxxxx
G20
31.3 kW (HI) 3.31 m
3
/hr
230 VAC
4 Amps
1
50 Hz
3 Wires, 1 Pole 1N-1G
8.7 mB
1633-xxx-X-Kxxxx
G25
25.7 kW (HI) 3.0 m
3
/hr
230 VAC
4 Amps
1
50 Hz
3 Wires, 1 Pole 1N-1G
8.7 mB
1633-xxx-X-Kxxxx
G25.3
25.4 kW (HI) 2.97 m
3
/hr
230 VAC
4 Amps
1
50 Hz
3 Wires, 1 Pole 1N-1G
8.7 mB
1634-xxx-X-Kxxxx
G30
34.2 kW (HI) 1.06 m
3
/hr
230 VAC
4 Amps
1
50 Hz
3 Wires, 1 Pole 1N-1G
24.8 mB
1634-xxx-X-Kxxxx
G31
30.9 kW (HI) 1.26 m
3
/hr
230 VAC
4 Amps
1
50 Hz
3 Wires, 1 Pole 1N-1G
24.8 mB
1635-xxx-X-Kxxxx Nat. Gas
110,000 BTU/hr
220 VAC
4 Amps
1
60 Hz
3 Wires, 1 Pole 1N-1G
0.87 kPa
1636-xxx-X-Kxxxx
LP Gas
110,000 BTU/hr
220 VAC
4 Amps
1
60 Hz
3 Wires, 1 Pole 1N-1G
0.87 kPa
* Reference Model Number Key, Section 1.
Gas Pressure Conversion Chart
Inches of Water
Column
kPa
m-Bar
Millimeters of
Water Column
3.5
0.87
8.7
88.9
4.5
1.12
11.2
114.3
7
1.74
17.4
177.8
10
2.48
24.87
254.0
10.5
2.61
26.11
266.7
11
2.73
27.36
279.4
14
3.48
34.81
355.6
14.5
3.61
36.05
368.3
Electrical Supply for Gas 1600 Ovens in Australia:
Single Phase: 240 VAC, 50 Hz / 20 Amp: one neutral and
one earth/ground.
NOTE: In Australia, use a 10 Amp General Purpose Outlet.
All ovens require separate service and decidated neutral.
NOTE: For proper operation, the gas valve requires a
nominal inlet pressure of 7 inches H
2
O column for natural
gas and 11 inches of H
2
O column for L.P. gas. A minimum
inlet pressure of 1.0 inch of H
2
O above the manifold setting
(NAT. manifold 3.5 inch H
2
O, L.P. manifold 10 inch H
2
O) must
be maintained with no pressure drop from the no load to
full load condition. The maximum inlet pressure must be
maintained at or below 1/2 psig (14.5 inches H
2
O column).
Refer to the chart on the left for pressure conversions.
Содержание Lincoln Impinger 1600 Series
Страница 20: ...20 Document LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 9 20 Operation Section 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...44 Document LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 9 20 Charts Section 8 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 49: ...Document LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 9 20 Notes ...
Страница 50: ...50 Document LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 9 20 Notes ...
Страница 51: ...Document LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 9 20 Section 9 Diagrams THIS PAGE INTENTIONALLY LEFT BLANK ...