34
Document #: LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 – 9/20
Controls
Section 6
B. Programming displayed temperature/time as a
Preset:
Note: Before programming new values for a preset,
the oven must be currently running with the desired
temperature and time settings in the Display. (ex: 400F and
5:00)
1. Press and hold the desired control key to be used for
the preset {1}, {2}, {3}, or {4}. After four seconds, the
display will change from TEMP/TIME or PRESET (1-4) to
PRESET 1 (2, 3, or 4). Do not release key.
Continue to hold another 10-15 seconds until
PRESET 1/UPDATED is displayed. Release key.
UPDATED remains displayed for 3-5 seconds.
The selected temperature and time (ex: 400F and 5:00)
has been confirmed as Preset 1.
C. Selecting a Preset:
Press and hold the desired control key {1}, {2}, {3}, or {4}.
After four seconds, the display will change from TEMP/TIME
or PRESET (1-4) to PRESET 1 (2, 3, or 4).
.
Release key immediately. Preset 1 is now active and
PRESET 1 ACTIVATED displayed for 3 seconds and then
reverts back to PRESET 1 as shown on the following
illustrations:
The control will now operate with the time and
temperature settings that were stored into PRESET 1.
Each of the four PRESET keys are set and selected in
the same manner.
Содержание Lincoln Impinger 1600 Series
Страница 20: ...20 Document LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 9 20 Operation Section 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 44: ...44 Document LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 9 20 Charts Section 8 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 49: ...Document LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 9 20 Notes ...
Страница 50: ...50 Document LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 9 20 Notes ...
Страница 51: ...Document LIN_GO_SM_IMPLOPRO_S1600_INTL_4605727 9 20 Section 9 Diagrams THIS PAGE INTENTIONALLY LEFT BLANK ...